BEE 4750/5750 · Environmental Systems Analysis

Can the Lake Come Back?

A town earns more by sending more phosphorus into its lake. Push too far and the lake turns green, and cutting back to just below the loading that tipped it doesn't bring it back.

Grow the Town

Farms and a wastewater plant send phosphorus (P) into a lake. Each year you set the town's loading, \(L\), in µg/L per year. The town earns $1M a year for each unit of loading. The lake's P concentration then changes for one year, and if it ends the year above 25 µg/L, algal blooms cost the town $20M in tourism, fishing and water treatment.

The lake starts clear, at 8.3 µg/L, which is where it settles with a loading of 5, and the slider starts at 5. You have 30 years. Make the town as much money as you can.

Two Stable States

Two feedbacks compete. P leaves the water through the outflow and permanent burial in the sediment at a rate proportional to the concentration, \(sP\) with \(s = 0.6\) per year: a dampening feedback. P also comes back out of the sediment, slowly at low concentrations and quickly once the P feeds enough algae that their decay uses up the oxygen at the lake bottom: an amplifying feedback. Each year,

\[P_{t+1} = P_t + L - sP_t + R(P_t), \qquad R(P) = r\,\frac{P^q}{m^q + P^q},\] where \(R(P)\) is the release from the sediment, \(r = 20\) µg/(L·yr) is its maximum, \(m = 30\) µg/L is the concentration at which it reaches half of \(r\), and \(q = 8\) sets how steeply it rises around \(m\).

The lake is at an equilibrium, \(\hat P\), where the sources (loading plus sediment release) equal the losses. Move the loading and watch the equilibria appear and disappear.

Loading \(L\) (µg/L per year)
8.0

Sources and losses

Bifurcation diagram: equilibria for every loading

The feedback gain at an equilibrium is the slope of the sediment release minus the loss rate, \(g = R'(\hat P) - s\). Where \(g < 0\) the dampening feedback wins: a small push dies away and the equilibrium is stable. Where \(g > 0\) the push grows and the equilibrium is unstable. At \(L = 8\) there are three equilibria, at 13.4, 30.0 and 45.5 µg/L, with gains of −0.6, +0.7 and −0.5.

With \(F(P) = P + L - sP + R(P)\), so that \(P_{t+1} = F(P_t)\), an equilibrium is stable when \(|F'(\hat P)| < 1\). Since \(F' = 1 + g\) and \(R' \ge 0\), the gain is never below \(-s = -0.6\), so here \(g < 0\) is enough for stability. \[R'(P) = \frac{r\,q\,(P/m)^q}{P\,\left(1 + (P/m)^q\right)^2}\]

The unstable equilibrium is a boundary: a lake below it moves toward the clear equilibrium, and a lake above it moves toward the green one, as the arrows in the left chart show. A year or two of high loading moves P only a little, so the lake tips only if P is pushed past the boundary.

Before you read on

Loading was held at 13 and the lake turned green. The town cuts loading to 11, below the 11.7 at which the clear state disappears. Does the lake recover?

Between \(L = \) 5.3 and \(L = \) 11.7 the lake has two stable states, the clear (oligotrophic) and green (eutrophic) ones, and which one it is in depends on where it has been. This is hysteresis, and the range of loadings with two stable states is the window. Above 11.7, the eutrophication threshold, the clear state no longer exists, so a lake held there turns green, slowly at first when the loading is only just past 11.7: held at 11.75, it takes decades to pass 30 µg/L. To come back, the loading has to fall below 5.3, the recovery threshold, where the green state no longer exists. The dots on the bifurcation diagram are your 30 years from the first game; they sit off the curve while the lake is still moving toward an equilibrium.

Restore a Green Lake

A new town inherits a lake that tipped years ago: loading is 8 and P sits at 45.5 µg/L. Income and bloom costs are the same as in the first game. You have 30 years.

Wet and Dry Years

Actual loading isn't set exactly: rain washes more P off the fields in wet years and less in dry ones. Here each year's loading is the planned loading times a weather factor, drawn independently each year, with mean 1. The logarithm of the factor is Gaussian with standard deviation 0.25 (the factor is lognormal), so a planned 10 is 7.5 or less about one year in six and 12.4 or more about one year in six. The town still earns $1M a year for each unit of planned loading, and pays for blooms as before.

Choose one planned loading for 50 years, starting from the clear lake at 8.3 µg/L, and simulate 1,000 weather sequences. A sequence counts as tipped if P passes 35 µg/L in any year.

\[L_t = L_\text{planned}\, w_t, \qquad \log w_t \sim \mathcal{N}\!\left(-\tfrac{1}{2}(0.25)^2,\ (0.25)^2\right), \qquad \text{so } \mathbb{E}[w_t] = 1.\]

Before you simulate

Which planned loading earns the town the most on average over 50 years?

10.00

P in 40 of the sequences

Sequences that tip, by planned loading

Average net income per year, by planned loading

How Sharp Is the Threshold?

The exponent \(q\) sets how sharply the sediment release rises around \(m = 30\) µg/L, where it reaches half its maximum. It is a property of the lake, not a choice the town makes, and it is estimated from data, so it is never known exactly. Change it and watch the window between the thresholds.

Steepness \(q\)
8.0

Sediment release and the loss line

Bifurcation diagram

When \(q\) is below about 3.3, the release curve is never steeper than the loss line, the gain is negative everywhere, and the lake has a single equilibrium for every loading: it responds smoothly and comes back when loading falls. The steeper the release, the wider the window and the deeper the cut needed to recover. With \(q = 12\) the thresholds are 3.6 and 13.1.

Fifty Years of Boring Data

The maximum release rate \(r\) is not really a constant. It is \(\kappa M\), where \(M\) is the P stored in the sediment (in µg per litre of lake water) and \(\kappa\) is the share of it the sediment can release in a year. \(M\) is a stock that fills over decades. Split the loss rate \(s\) into the outflow and permanent burial, \(s_\text{out}\), and settling into the sediment, \(h\), and let \(b\) be the rate at which sediment P is buried for good:

\[P_{t+1} = P_t + L - s_\text{out}P_t - hP_t + \kappa M_t\,\frac{P_t^q}{m^q + P_t^q},\] \[M_{t+1} = M_t + hP_t - bM_t - \kappa M_t\,\frac{P_t^q}{m^q + P_t^q},\] with \(s_\text{out} = 0.2\), \(h = 0.4\) (so \(s_\text{out} + h = s\)), \(b = 0.015\) and \(\kappa = 0.1\) per year. The lake starts at \(P = L/s\) with an empty sediment, \(M = 0\). In any year, the eutrophication threshold is the one-stock model's threshold with \(r = \kappa M\) for that year.

Before you look

A town holds its loading at 11.5, an apparently safe level just below the 11.7 eutrophication threshold, for 140 years. Does the lake stay clear?